order number
Technical Parameters
UN 288-3AM06-0AA0
physical properties
Dimensions W x H x D (mm)
45 x 100 x 81
power consumption
2W (no load)
Power Characteristics
Rated voltage
DC 24V
Input voltage
DC 20.4 to 28.8V
24V input current
Less than 100mA (no load)
electric shock
12A at 28.8V DC
Insurance
0.75A 60V slow blow
SM bus current
Less than 120mA (single module)
Analog Input Characteristics
Enter points
4 inputs
Analog input type
Analog differential input
Voltage Input Range (Bipolar)
±10V, ±5V, ±2.5V
Voltage data range
-27648 ~+27648
Current data range
0 ~ 27648
Current input range
0 ~ 20mA
Overshoot/Undershoot Range (data word)
Voltage: 27,649~32,511/-27,649~-32,512
Current: 27,649~32,511/-4,864~0
Overflow/Underflow (data word)
Voltage: 32,512~32,767/-32,513~-32,768
Current: 32,512~32,767/-4,865~-32,768
resolution
Voltage mode: 12 bits + sign bit
Current Mode: 12 bits
Maximum pressure/current resistance
± 30 V / ± 40 mA (withstand voltage)
smoothing
none, weak, medium or strong
noise suppression
400 , 60, 50 or 10 Hz
Accuracy (25°C/0~50°C)
Voltage input: ±0.1%FS/±0.2%FS
Current input: ±0.2%FS/±0.3%FS
input resistance
≥2MΩ voltage input
250Ω current input
Isolation (Field to Logic)
>500V
ADC conversion time
625uS (400Hz suppression)
common mode rejection
40dB , DC to 60Hz
common mode voltage
Signal voltage + common mode voltage ≤ 12V
Cable length (maximum)
100m , shielded twisted pair
Analog Output Characteristics
output points
2 outputs
output type
voltage or current
Voltage output range
-10V ~ +10V
Current output range
0 ~ +20mA
resolution
Voltage mode: 11 bits + sign bit
Current Mode: 11 bits
Full-Scale Range (Data Words)
Voltage: -27648~+27648
Current: 0~27648
output buffer
Voltage: 27649~28000/-27648~-28000
Current: 0~-4864
Accuracy (25°C/0~50°C)
Voltage: ±0.5%FS /±1%FS, Current: ±1%FS
Settling time (95% of new value)
Voltage: 300 μs (R), 750 μs (1 μF)
Current: 600 μs (1 mH), 2 ms (10 mH)
load impedance
Voltage ≥ 1000Ω
Current ≤ 500Ω
Output status in STOP mode
previous value or replacement value (default is 0)
Isolation (Field to Logic)
>500V
Cable length (maximum)
Text
diagnosis
overflow/underflow
support
Short to ground (voltage mode only)
support
Open Circuit (Current Mode Only)
support
24 V DC
support
Environment and basic parameters
Working temperature
0 °C~60°C (horizontal installation), 0°C~50°C (vertical installation)
Transport ambient temperature
-20 ℃~80℃
Ambient relative humidity
5 ~ 90%, non-condensing (RH level 2, in line with IEC61131-2)
degree of protection
IP20 , comply with IEC60529